Electrostatic Automatic Powder Coating Gun High Powder Usage Rate M2 Spray Gun
Powder Coating Machine for Metal Parts; High Powder Usage Rate and Low Waste; Help to Increase Production Capability; 100-240V Self Adaptive.
Electrostatic Automatic Powder Coating Gun High Powder Usage Rate M2 Spray Gun
***Product and Feature
Model No.: M2
Brand: JOBON
Manufacturing Origin: China
Certified: CE, ATEX
M2 Electrostatic Powder Coating Gun Parameter
Application: Powder coating machine for metal parts
Advantage: High powder usage rate and low waste
Feature: Help to improve line speed and increase production capacity
Powder Supply: AC 100-240/50-60HZ(self-adaptive)
Max Power: 50Watt
Safety Level: IP54
Input Temperature: 0-40℃(+32~+104℉)
Electrostatic Polarity: Negative
Max Output Pressure: 130KV
Mx Output Current:100uA
Pistol Power Cord Length: 3.8m
Powder Piple Length: 3.5m
Max Powder Output: 650g/min
Volumn of Hopper: 52L
Max Water Concentration in compressed air: 1.3g/m³
Max Oil Concentration in compressed air: 0.1g/m³



***Working Video
***Warm tips:
1. We have 1000 sets M2 powder coating machines and 500Sets powder coating machines so we can make shipment immediately.
2. We have both manual type and automatic type of our M2 and S20 powder coating machine, so the automatic guns can fit the reciprocators really well.
3. The gun is controlled by PLC that we programmed by oiurselves, so it is more stable with better performance.
***To summarize the reasons why no powder coming out of the spray gun, there are probably the following:
1. The powder outlet of the spray gun is blocked by the diffuser nozzle(mostly occurs in new guns);
2. The solenoid valve does not work, and no injection air output;
3. The powder pipe connected to the spray gun is bent, blocked, or falls off, and the air pressure connection pipes are wrongly connected (the injection air and dilution air are reversed)
4. The inlet valve is not opened, or the air pressure is too low
5. The gun control wire, trigger switch, and the socket connecting the gun pistol to the gun control unit have poor contact (no click sound in the main unit when the trigger is pulled)
6. Dilution pressure is too large
7. The powder nozzle on the powder suction pump is blocked
8. Severe wear of the Venturi tube
How to solve it?
1. Adjust the diffuser nozzle's position outward;
2. Check the plug and wiring of the solenoid valve;
3. Check the powder pipe and each air pipe;
4. Open the valve and adjust the injection air pressure to above 0.15;
5. Check wiring and plugs;
6. Turn off the dilution air pressure completely to test the machine;
7. Clean up the machine and inspect it frequently;
8. Check and replace the Venturi tube;